World-Class Surgical Suites

Zero Infection.
Absolute Precision.

We engineer NABH-compliant Modular Operation Theaters. Featuring antibacterial surfaces, Class 10,000 laminar airflow, and smart surgeon control panels designed for flawless, high-stakes surgical outcomes.

Infections Don't Happen By Accident.
They Happen By Design.

A standard room with an AC is NOT an Operation Theater. Surgical site infections (SSIs) are the leading cause of post-op complications. A true Modular OT utilizes seamless hermetic sealing, positive pressure HEPA filtration, and anti-static flooring to guarantee a 99.9% sterile environment. Don't compromise when lives are on the table.

Anatomy of a Smart OT

Every square inch is engineered using medical-grade materials and IoT technology.

Antibacterial PUF Panels

Seamless Stainless Steel (SS 304) or Pre-Painted Galvanized Iron (PPGI) wall and ceiling panels. Designed with curved covings to eliminate 90-degree dust-gathering corners.

Laminar Airflow (LAF)

Ceiling-mounted HEPA filter plenums that push sterile air directly down over the operating table, pushing away airborne bacteria through return air risers.

Anti-Static Epoxy Flooring

Conductive, seamless 2mm-3mm epoxy or vinyl flooring. Discharges static electricity safely to the ground, preventing sparks near sensitive oxygen and anesthesia lines.

Hermetically Sealed Doors

Automatic sensor-operated sliding doors that seal airtight. Maintains vital positive air pressure inside the OT and prevents outside corridor air from entering.

Surgeon Control Panel

A flush-mounted digital touchscreen interface allowing the surgical team to control OT temperature, humidity, lighting, medical gases, and view live X-Ray/PACS data.

OT Audio/Visual Integration

High-resolution ceiling cameras and boom-arm monitors. Perfect for recording complex surgeries, live broadcasting for medical students, or tele-consultation.

Technical Specifications

Parameter Standard Execution / Compliance
Compliance Standards NABH, ISO 14644-1, ASHRAE Standard 170
Cleanroom Class Class 10,000 / Class 1,000 (As per surgical requirement)
Wall/Ceiling Material SS 304 / EGP / PUF Sandwiched Panels (0.8mm - 1.0mm)
Filtration System HEPA Filters (99.997% efficiency down to 0.3 microns)
Air Changes Per Hour (ACPH) 25 - 30 ACPH (Minimum 4 fresh air changes)
Medical Gas Pipeline System Flush-mounted concealed copper pipelines (O2, N2O, Vacuum, Air)
Electrical Safety Isolated Power Supply (IPS) panel with extreme overload protection

Build Your Masterpiece

Whether it's a minor day-care OT or a massive Neuro/Cardiac Surgical Suite, our biomedical engineers handle the turnkey execution from bare brick to the first surgery.