Zero Infection.
Absolute Precision.
We engineer NABH-compliant Modular Operation Theaters. Featuring antibacterial surfaces, Class 10,000 laminar airflow, and smart surgeon control panels designed for flawless, high-stakes surgical outcomes.
Infections Don't Happen By Accident.
They Happen By Design.
A standard room with an AC is NOT an Operation Theater. Surgical site infections (SSIs) are the leading cause of post-op complications. A true Modular OT utilizes seamless hermetic sealing, positive pressure HEPA filtration, and anti-static flooring to guarantee a 99.9% sterile environment. Don't compromise when lives are on the table.
Anatomy of a Smart OT
Every square inch is engineered using medical-grade materials and IoT technology.
Antibacterial PUF Panels
Seamless Stainless Steel (SS 304) or Pre-Painted Galvanized Iron (PPGI) wall and ceiling panels. Designed with curved covings to eliminate 90-degree dust-gathering corners.
Laminar Airflow (LAF)
Ceiling-mounted HEPA filter plenums that push sterile air directly down over the operating table, pushing away airborne bacteria through return air risers.
Anti-Static Epoxy Flooring
Conductive, seamless 2mm-3mm epoxy or vinyl flooring. Discharges static electricity safely to the ground, preventing sparks near sensitive oxygen and anesthesia lines.
Hermetically Sealed Doors
Automatic sensor-operated sliding doors that seal airtight. Maintains vital positive air pressure inside the OT and prevents outside corridor air from entering.
Surgeon Control Panel
A flush-mounted digital touchscreen interface allowing the surgical team to control OT temperature, humidity, lighting, medical gases, and view live X-Ray/PACS data.
OT Audio/Visual Integration
High-resolution ceiling cameras and boom-arm monitors. Perfect for recording complex surgeries, live broadcasting for medical students, or tele-consultation.
Technical Specifications
| Parameter | Standard Execution / Compliance |
|---|---|
| Compliance Standards | NABH, ISO 14644-1, ASHRAE Standard 170 |
| Cleanroom Class | Class 10,000 / Class 1,000 (As per surgical requirement) |
| Wall/Ceiling Material | SS 304 / EGP / PUF Sandwiched Panels (0.8mm - 1.0mm) |
| Filtration System | HEPA Filters (99.997% efficiency down to 0.3 microns) |
| Air Changes Per Hour (ACPH) | 25 - 30 ACPH (Minimum 4 fresh air changes) |
| Medical Gas Pipeline System | Flush-mounted concealed copper pipelines (O2, N2O, Vacuum, Air) |
| Electrical Safety | Isolated Power Supply (IPS) panel with extreme overload protection |